IFM SI5002 Flow Monitor — calorimetric flow monitor, M18 process connection, liquids & gases, IO-Link, LED bar graph. Calorimetric flow monitor, M18x1.5, liquids 3...300 cm/s & gases 200...3000 cm/s, 2 x PNP + IO-Link, LED bar graph, IP67, 18...36 V DC, 300 bar.
Shipping & Returns
Same-day dispatch across UAE
Order before 2 PM (Sun–Thu). Next-day delivery to Dubai, Sharjah, Abu Dhabi. 2–4 days to other emirates.
7-day return window
Sealed, unused items can be returned within 7 days for full refund or replacement.
Compatibility-checked
Our specialists review every bulk quote to ensure the part fits your application before you commit.
MPN / SKU: SI5002
Also known as: IFM SI5002 flow sensor / flow switch / flow meter.
SI5002 Applications
The IFM SI5002 is a calorimetric flow monitor used for reliable monitoring of liquids and gases in pipes. It is suited for pump-protection, cooling-water and lubrication flow monitoring, and dry-run detection in industrial machinery. Variable process connection via adapters allows flexible installation, switch points are set quickly by pushbutton or IO-Link, and the 10-segment three-colour LED bar graph clearly indicates flow and switch point. The robust stainless steel housing withstands harsh industrial and washdown environments.
What flow velocity range does the IFM SI5002 measure?
The SI5002 measures flow velocity from 3 to 300 cm/s in liquids and from 200 to 3000 cm/s in gases.
What measuring principle does the SI5002 flow monitor use and what media does it suit?
It is a thermal (calorimetric) flow monitor with a 45 mm probe length, suitable for liquids and gases.
How accurate and responsive is the IFM SI5002?
Switch point accuracy is +/- 2 to +/- 10 cm/s (water, 25 C, factory setting) with a repeatability of 1 to 5 cm/s and a response time of 1 to 10 seconds.
What outputs does the SI5002 provide?
It has 2 digital outputs of PNP design, configurable as switching signal or IO-Link, rated at 250 mA permanent current with a maximum voltage drop of 2.5 V DC, and short-circuit and overload protected.
Does the SI5002 support IO-Link and at what specification?
Yes, it supports IO-Link revision 1.1 with COM2 transmission at 38.4 kBaud.
What is the operating voltage and current consumption of the SI5002?
The SI5002 operates on 18 to 36 V DC and draws less than 60 mA.
What is the housing material and IP rating of the IFM SI5002?
The cylindrical housing is made of stainless steel (316L/1.4404 and 301/1.4310), PC, PBT-GF20 and EPDM/X, with protection rating IP 65 and IP 67.
What are the process and electrical connections of the SI5002?
The process connection is an M18 x 1.5 internal thread and the electrical connection is 1 x M12 A-coded 4-pin connector; operating temperature is -25 to 80 C.
Being a UAE company, our UAE shipments are subject to tariffs. Under DDP (Delivered Duty Paid), all applicable tariffs and fees are calculated and paid upfront at checkout.
Same-day dispatch across UAE
Order before 2 PM (Sun–Thu). Next-day delivery to Dubai, Sharjah, Abu Dhabi. 2–4 days to other emirates.
7-day return window
Sealed, unused items can be returned within 7 days for full refund or replacement.
Compatibility-checked
Our specialists review every bulk quote to ensure the part fits your application before you commit.