IFM PK5524 Pressure Switch — mechanical pressure switch 0...10 bar with setting ring, stainless cell, G1/4. pressure switch with setting-ring switch-point adjustment, 0...10 bar, stainless steel measuring cell, 1 PNP output, mechanical locking, high burst pressure, G1/4, IP67.
The IFM PK5524 pressure switch offers simple switch-point setting via a scaled setting ring, with a stainless cell for chemical compatibility and mechanical locking to prevent tampering, for hydraulic and pneumatic monitoring.
What is the pressure and setting range of the IFM PK5524 pressure switch?
The PK5524 has a measuring range of 0...10 bar (0...145 psi) and a setting range of 0.5...10 bar (7.5...145 psi).
What is the overpressure capability of the PK5524?
The PK5524 has a pressure rating of 25 bar (362 psi / 2.5 MPa) and a minimum burst pressure of 300 bar (4350 psi / 30 MPa).
What media and accuracy does the PK5524 offer?
The PK5524 measures liquids and gases with a switch point (setting) accuracy of < ± 2.5 %, repeatability of < ± 0.5 % (with temperature fluctuations < 10 K), and a hysteresis of 0.2 bar (2.9 psi).
What output and ratings does the IFM PK5524 have?
The PK5524 has one PNP digital output, normally open, with a permanent current rating of 500 mA, a maximum voltage drop of 2 V DC, and a switching frequency of 100 Hz.
What is the operating voltage of the PK5524?
The PK5524 operates on 9.6...32 V DC with a current consumption of < 25 mA, and includes reverse polarity, pulsed short-circuit, and overload protection.
What are the wetted materials and IP rating of the PK5524?
The PK5524 housing uses PBT, PC, FKM, and stainless steel (316L/1.4404), with wetted parts of stainless steel (316L/1.4404) and FKM. It is rated to IP 67.
How is the switch point set on the IFM PK5524?
The switch point on the PK5524 is set with a setting ring that includes a scale.
What are the temperature range and connections of the PK5524?
The PK5524 has an ambient and medium temperature range of -25...80 °C (storage -40...100 °C), a G 1/4 external thread (with M5 internal thread) process connection, and an M12 connector, A-coded, with 4 contacts.