Skip to product information
1 of 1

IFM AC2900 - AS-Interface ProcessLine Module, AS-i 8-Port, IP69K

IFM AC2900 - AS-Interface ProcessLine Module, AS-i 8-Port, IP69K

SKUAC2900BrandIFM
Regular price AED 964.47
Regular price AED 1,071.64 Sale price AED 964.47
Sale Sold out
Shipping calculated at checkout.

IFM AC2900 AS-Interface ProcessLine Module — hygienic stainless AS-i I/O module, 8 x M12, IP69K, food-industry wet areas. AS-Interface ProcessLine I/O module for wet areas of the food and beverage industry, hygienic stainless design without corners, 8 x M12 ports, AS-i and 24 V via a common M12, high-pressure-clean resistant, IP69K.

Shipping & Returns

Same-day dispatch across UAE

Order before 2 PM (Sun–Thu). Next-day delivery to Dubai, Sharjah, Abu Dhabi. 2–4 days to other emirates.

7-day return window

Sealed, unused items can be returned within 7 days for full refund or replacement.

Compatibility-checked

Our specialists review every bulk quote to ensure the part fits your application before you commit.

MPN / SKU: AC2900

Also known as: IFM AC2900 as-i module / as-interface i/o module / asi module.

AC2900 Applications

The IFM AC2900 AS-Interface ProcessLine module connects sensors and actuators in the wet areas of food and beverage plants, with a hygienic corner-free stainless housing resistant to aggressive high-pressure cleaning and IP69K sealing.

AC2900 Specifications

Brand IFM Product Type AS-Interface ProcessLine module
Product type code ProcessLine 8 SB IP69K Ports 8 x M12 (5-pin)
Supply AS-i + 24 V via common M12 Operating voltage 26.5...31.6 V DC
Material Stainless steel (hygienic) Protection IP 68; IP 69K
Weight 613.5 g

AC2900 – Frequently Asked Questions (FAQ)

What is the IFM AC2900 used for?

It is an AS-Interface ProcessLine module designed for hygienic and wet areas in food industry applications.

How many ports does the AC2900 have?

It has 8 M12 socket connections plus 1 M12 plug connection, all A-coded.

What is the maximum current load of the AC2900?

The maximum current load per module/slot is 4 A (AS-i: 4 A; AUX: 4 A).

What operating voltages does the AC2900 use?

The AS-i supply is 26.5...31.6 V DC and the auxiliary supply is 20...30 V DC.

What communication standard does the AC2900 follow?

It communicates via AS-Interface per EN 62026-2, with a maximum cable length of 20 m for the socket connections.

What is the housing material and IP rating of the AC2900?

The housing is stainless steel with an EPDM O-ring, rated IP 68 and IP 69K with pollution degree 2.

What is the operating temperature range of the AC2900?

The ambient temperature range is -5...70 degrees C, with maximum relative air humidity of 90 % (non-condensing).

What is the recommended tightening torque for the AC2900 M12 connections?

The tightening torque is 1.2...1.4 Nm.

View full details

Same-day dispatch across UAE

Order before 2 PM (Sun–Thu). Next-day delivery to Dubai, Sharjah, Abu Dhabi. 2–4 days to other emirates.

7-day return window

Sealed, unused items can be returned within 7 days for full refund or replacement.

Compatibility-checked

Our specialists review every bulk quote to ensure the part fits your application before you commit.