IFM LDL200 Inductive Conductivity Sensor — inductive (toroidal) conductivity, 100...1,000,000 µS/cm, hygienic G1 Aseptoflex, IO-Link. inductive (toroidal) conductivity sensor for hygienic processes, range 100...1,000,000 µS/cm plus temperature, hygienic G1 Aseptoflex Vario connection, analog 4...20 mA and IO-Link, 316L/PEEK, IP69K.
Shipping & Returns
Same-day dispatch across UAE
Order before 2 PM (Sun–Thu). Next-day delivery to Dubai, Sharjah, Abu Dhabi. 2–4 days to other emirates.
7-day return window
Sealed, unused items can be returned within 7 days for full refund or replacement.
Compatibility-checked
Our specialists review every bulk quote to ensure the part fits your application before you commit.
MPN / SKU: LDL200
Also known as: IFM LDL200 conductivity sensor / conductivity meter / conductivity probe.
LDL200 Applications
The IFM LDL200 inductive conductivity sensor measures a very wide conductivity range plus temperature in CIP and process liquids, its hygienic wear-free toroidal design improving phase separation and reducing water and cleaning-agent use.
What is the conductivity measuring range of the IFM LDL200?
The LDL200 measures conductivity from 100...1000000 µS/cm using the inductive measuring principle.
How accurate is the LDL200 conductivity sensor?
The LDL200 has a conductivity accuracy of 2 % of measured value ± 25 µS/cm, a repeatability of 1 % of measured value ± 25 µS/cm, and a response time of < 2 seconds for conductivity.
What is the resolution of the IFM LDL200 across its range?
The LDL200 resolves conductivity at 1 µS/cm from 0...10,000, 10 µS/cm from 10,000...100,000, and 100 µS/cm from 100,000...1,000,000 µS/cm.
What output does the LDL200 provide?
The LDL200 has one analogue current output of 4...20 mA with a maximum load of 500 Ω.
Does the LDL200 support IO-Link?
Yes, the LDL200 supports IO-Link revision 1.1 with COM2 transmission at 38.4 kBaud.
What is the operating voltage of the IFM LDL200?
The LDL200 operates on 18...30 V DC with a current consumption of < 100 mA and includes reverse polarity protection.
What are the wetted materials and IP rating of the LDL200?
The LDL200 uses stainless steel (316L/1.4404), PEEK, PEI, and FKM, and is rated to IP 68 and IP 69K with a pressure rating of 16 bar.
What are the temperature range and connections of the IFM LDL200?
The LDL200 handles a medium temperature of -25...100 °C (peak 150 °C short-term) with a measurement range of -25...150 °C, and an ambient temperature of -40...60 °C. It has a G 1 external thread Aseptoflex Vario process connection and an M12 connector.
Being a UAE company, our UAE shipments are subject to tariffs. Under DDP (Delivered Duty Paid), all applicable tariffs and fees are calculated and paid upfront at checkout.
Same-day dispatch across UAE
Order before 2 PM (Sun–Thu). Next-day delivery to Dubai, Sharjah, Abu Dhabi. 2–4 days to other emirates.
7-day return window
Sealed, unused items can be returned within 7 days for full refund or replacement.
Compatibility-checked
Our specialists review every bulk quote to ensure the part fits your application before you commit.