{"product_id":"si5010","title":"IFM SI5010 - Flow Monitor, IO-Link, 300 bar Rated","description":"\u003cp\u003eIFM SI5010 Flow Monitor — single PNP output plus IO-Link, 300 bar rated, pushbutton setup and LED bar graph. thermal (calorimetric) flow monitor for liquids and gases, M18 x 1.5 internal thread, 300 bar rated, 1 PNP output plus IO-Link, LED bar graph, pushbutton setup, stainless steel 316L housing, IP65\/IP67.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN \/ SKU:\u003c\/strong\u003e SI5010\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAlso known as:\u003c\/strong\u003e IFM SI5010 flow sensor \/ flow switch \/ flow meter.\u003c\/p\u003e\u003ch2\u003eSI5010 Applications\u003c\/h2\u003e\u003cp\u003eThe IFM SI5010 flow monitor detects flow of liquids and gases in pipes to protect pumps, cooling circuits and lubrication lines against dry running and blockages. Rated to 300 bar and fitted with an IO-Link interface alongside its PNP output, it suits high-pressure hydraulic and process applications and supports digital parameter setting and diagnostics. The 316L stainless steel housing withstands harsh industrial duty.\u003c\/p\u003e\u003ch2\u003eSI5010 Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eIFM\u003c\/td\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFlow monitor (thermal flow switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type code\u003c\/td\u003e\n\u003ctd\u003eSID10ADBFPKG\/US-100\u003c\/td\u003e\n\u003ctd\u003eMedia\u003c\/td\u003e\n\u003ctd\u003eLiquids; gases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedium temperature\u003c\/td\u003e\n\u003ctd\u003e-25...80 °C\u003c\/td\u003e\n\u003ctd\u003ePressure rating\u003c\/td\u003e\n\u003ctd\u003e300 bar (30 MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess connection\u003c\/td\u003e\n\u003ctd\u003eM18 x 1.5 internal thread\u003c\/td\u003e\n\u003ctd\u003eOperating voltage\u003c\/td\u003e\n\u003ctd\u003e18...36 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003e1 x PNP switching; IO-Link\u003c\/td\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eIO-Link 1.1 (COM2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting range (liquids)\u003c\/td\u003e\n\u003ctd\u003e3...300 cm\/s\u003c\/td\u003e\n\u003ctd\u003eSetting range (gases)\u003c\/td\u003e\n\u003ctd\u003e200...3000 cm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eIP 65; IP 67\u003c\/td\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003eStainless steel 1.4404 \/ 316L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e248.5 g\u003c\/td\u003e\n\u003ctd\u003eElectrical connection\u003c\/td\u003e\n\u003ctd\u003eM12 connector, A-coded, 4 contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSI5010 Datasheet \u0026amp; Manual\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/media.ifm.com\/dam\/5602f716-67e6-4795-b008-b0702874baba\/Original\/SI5010-04_EN-GB.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload IFM SI5010 Datasheet \u0026amp; Manual (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSI5010 -- Frequently Asked Questions (FAQ)\u003c\/h2\u003e\u003cdiv class=\"ha-faq\"\u003e\n\u003cdiv class=\"ha-faq-item\"\u003e\n\u003cp class=\"ha-faq-q\"\u003eWhat is the IFM SI5010?\u003c\/p\u003e\n\u003cp class=\"ha-faq-a\"\u003eIFM SI5010 is a Flow Monitor -- single PNP output plus IO-Link, 300 bar rated, pushbutton setup and LED bar graph.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ha-faq-item\"\u003e\n\u003cp class=\"ha-faq-q\"\u003eWhat is the IFM SI5010 used for?\u003c\/p\u003e\n\u003cp class=\"ha-faq-a\"\u003eThe IFM SI5010 flow monitor detects flow of liquids and gases in pipes to protect pumps, cooling circuits and lubrication lines against dry running and blockages.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ha-faq-item\"\u003e\n\u003cp class=\"ha-faq-q\"\u003eWhat are the key specifications of the IFM SI5010?\u003c\/p\u003e\n\u003cp class=\"ha-faq-a\"\u003eIFM SI5010 -- thermal (calorimetric) flow monitor for liquids and gases, M18 x 1.5 internal thread, 300 bar rated, 1 PNP output plus IO-Link, LED bar graph, pushbutton setup, stainless steel 316L housing, IP65\/IP67.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ha-faq-item\"\u003e\n\u003cp class=\"ha-faq-q\"\u003eWhat output or connection does the IFM SI5010 have?\u003c\/p\u003e\n\u003cp class=\"ha-faq-a\"\u003eThe IFM SI5010 has -- Output: 1 x PNP switching; IO-Link.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ha-faq-item\"\u003e\n\u003cp class=\"ha-faq-q\"\u003eWhere can I get the IFM SI5010 datasheet?\u003c\/p\u003e\n\u003cp class=\"ha-faq-a\"\u003eThe official IFM SI5010 datasheet (PDF) is linked in the Datasheet \u0026amp; Manual section on this page.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"IFM","offers":[{"title":"Default Title","offer_id":47702931931273,"sku":"SI5010","price":1163.56,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0693\/5622\/4649\/files\/SI5010.jpg?v=1785439221","url":"https:\/\/www.creativeautomation.ae\/products\/si5010","provider":"Creative Industrial Automation","version":"1.0","type":"link"}