{"product_id":"pn2694","title":"IFM PN2694 - Pressure Sensor with Display, -1...10 bar, 1\/4\" NPT External","description":"\u003c!--ifm-style-v2--\u003e\u003cstyle\u003e.ifm-desc{font-size:15px;line-height:1.65;color:#3a3a3a}.ifm-desc h2{text-transform:uppercase;font-size:13px;font-weight:700;letter-spacing:1.2px;color:#2b2b2b;margin:38px 0 18px;padding-bottom:11px;border-bottom:2px solid #e0521e}.ifm-desc h2:first-of-type{margin-top:22px}.ifm-desc p{margin:0 0 14px}.ifm-desc table{width:100%;border-collapse:collapse;margin:2px 0 10px;font-size:14px;border:1px solid #e6e6e6}.ifm-desc table td{border:1px solid #ececec;padding:13px 16px;vertical-align:top}.ifm-desc table td:nth-child(odd){background:#f4f5f6;font-weight:700;color:#333;width:16%}.ifm-desc .ha-2col{margin:0}.ifm-desc .ha-dl{display:inline-flex;align-items:center;gap:16px;background:linear-gradient(135deg,#e8642a,#d24f18);color:#fff!important;text-decoration:none!important;padding:16px 26px;border-radius:12px;box-shadow:0 4px 14px rgba(210,79,24,.28);font-weight:700;font-size:15px;line-height:1.2;margin-top:2px}.ifm-desc .ha-dl:hover{filter:brightness(1.06)}.ifm-desc .ha-dl-ic{display:flex;align-items:center;justify-content:center;width:42px;height:42px;background:rgba(255,255,255,.2);border-radius:9px;flex-shrink:0}.ifm-desc .ha-dl small{display:block;font-size:12px;font-weight:500;opacity:.92;margin-top:3px}.ifm-desc .ha-faq{margin-top:4px}.ifm-desc .ha-faq-item{border-top:1px solid #ececec;padding:13px 0}.ifm-desc .ha-faq-item:last-child{border-bottom:1px solid #ececec}.ifm-desc .ha-faq-q{font-weight:700;color:#1f1f1f;margin:0;font-size:15px;cursor:pointer;list-style:none;position:relative;padding-right:30px}.ifm-desc .ha-faq-q::-webkit-details-marker{display:none}.ifm-desc .ha-faq-item summary::after{content:\"+\";position:absolute;right:2px;top:50%;transform:translateY(-50%);color:#e0521e;font-size:22px;font-weight:400;line-height:1}.ifm-desc .ha-faq-item[open] summary::after{content:\"−\"}.ifm-desc .ha-faq-item[open] .ha-faq-q{color:#e0521e}.ifm-desc .ha-faq-a{margin:10px 0 2px;color:#555}.ifm-desc a:not(.ha-dl){color:#e0521e;font-weight:600;text-decoration:none}.ifm-desc a:not(.ha-dl):hover{text-decoration:underline}@media(min-width:990px){.product:has(.ifm-desc){align-items:flex-start}.product:has(.ifm-desc) .product__media-wrapper{align-self:flex-start}.product__info-container:has(.ifm-desc){overflow:visible}.product__column-sticky:has(.ifm-desc){position:static}.ifm-desc{position:relative;z-index:1;background:#fff;box-sizing:border-box;width:202.5%;margin-left:-102.5%;margin-top:24px;padding-top:24px;border-top:1px solid #eee}}.ifm-desc .ifm-ship{border:1px solid #ececec;border-radius:14px;padding:20px 22px;margin:6px 0 26px}.ifm-desc .ifm-ship-head{font-weight:700;color:#e0521e;font-size:13px;text-transform:uppercase;letter-spacing:.6px;margin:0 0 16px;padding-bottom:12px;border-bottom:1px solid #f0f0f0}.ifm-desc .ifm-ship-grid{display:grid;grid-template-columns:repeat(3,1fr);gap:16px}@media(max-width:768px){.ifm-desc .ifm-ship-grid{grid-template-columns:1fr}}.ifm-desc .ifm-ship-card{display:flex;gap:12px;border:1px solid #eee;border-radius:12px;padding:15px 17px;background:#fafafa}.ifm-desc .ifm-ship-ic{color:#e0521e;flex-shrink:0;margin-top:1px}.ifm-desc .ifm-ship-t{font-weight:700;color:#1f1f1f;margin:0 0 5px;font-size:14.5px}.ifm-desc .ifm-ship-d{margin:0;color:#666;font-size:13px;line-height:1.5}#pdp-tab-shipping{display:none!important}#pdp-panel-shipping{display:none!important}#pdp-panel-tariffs{display:block!important}#pdp-tab-tariffs{color:#ff7a00!important;background:#fff!important;position:relative}#pdp-tab-tariffs::after{content:\"\";position:absolute;left:0;bottom:0;width:100%;height:3px;background:#ff7a00}\u003c\/style\u003e\u003cdiv class=\"ifm-desc\"\u003e\n\u003cp\u003eIFM PN2694 Pressure Sensor with Display — -1...10 bar range with a 1\/4\" NPT external thread, ceramic-capacitive cell and 2 switching + 1 analogue outputs plus IO-Link. -1...10 bar, 1\/4\" NPT external, ceramic-capacitive, 2 switching + 1 analogue (4...20 mA \/ 0...10 V), IO-Link, 18...30 V DC, IP 65 \/ IP 67.\u003c\/p\u003e\n\u003cdiv class=\"ifm-ship\"\u003e\n\u003cdiv class=\"ifm-ship-head\"\u003eShipping \u0026amp; Returns\u003c\/div\u003e\n\u003cdiv class=\"ifm-ship-grid\"\u003e\n\u003cdiv class=\"ifm-ship-card\"\u003e\n\u003csvg class=\"ifm-ship-ic\" width=\"20\" height=\"20\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpolyline points=\"15 3 21 3 21 9\"\u003e\u003c\/polyline\u003e\u003cpolyline points=\"9 21 3 21 3 15\"\u003e\u003c\/polyline\u003e\u003cline x1=\"21\" y1=\"3\" x2=\"14\" y2=\"10\"\u003e\u003c\/line\u003e\u003cline x1=\"3\" y1=\"21\" x2=\"10\" y2=\"14\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003cdiv\u003e\n\u003cp class=\"ifm-ship-t\"\u003eSame-day dispatch across UAE\u003c\/p\u003e\n\u003cp class=\"ifm-ship-d\"\u003eOrder before 2 PM (Sun–Thu). Next-day delivery to Dubai, Sharjah, Abu Dhabi. 2–4 days to other emirates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ifm-ship-card\"\u003e\n\u003csvg class=\"ifm-ship-ic\" width=\"20\" height=\"20\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.4\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003cdiv\u003e\n\u003cp class=\"ifm-ship-t\"\u003e7-day return window\u003c\/p\u003e\n\u003cp class=\"ifm-ship-d\"\u003eSealed, unused items can be returned within 7 days for full refund or replacement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ifm-ship-card\"\u003e\n\u003csvg class=\"ifm-ship-ic\" width=\"20\" height=\"20\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M22 11.08V12a10 10 0 1 1-5.93-9.14\"\u003e\u003c\/path\u003e\u003cpolyline points=\"22 4 12 14.01 9 11.01\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003cdiv\u003e\n\u003cp class=\"ifm-ship-t\"\u003eCompatibility-checked\u003c\/p\u003e\n\u003cp class=\"ifm-ship-d\"\u003eOur specialists review every bulk quote to ensure the part fits your application before you commit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eMPN \/ SKU:\u003c\/strong\u003e PN2694\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso known as:\u003c\/strong\u003e IFM PN2694 pressure sensor \/ pressure transmitter \/ pressure switch.\u003c\/p\u003e\n\u003ch2\u003ePN2694 Applications\u003c\/h2\u003e\n\u003cp\u003eThe IFM PN2694 electronic pressure sensor monitors the system pressure of liquids and gases over a -1...10 bar range with a ceramic-capacitive measuring cell and high overload strength (75 bar). Two configurable switching outputs plus one scalable analogue output (4...20 mA or 0...10 V) allow direct switching and continuous signal transmission, while IO-Link enables digital parameter setting, diagnostics and process-value transmission. A rotatable 4-digit red\/green display shows the process value, suiting industrial machinery and plant.\u003c\/p\u003e\n\u003ch2\u003ePN2694 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eIFM\u003c\/td\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePressure sensor with display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIFM Type Code\u003c\/td\u003e\n\u003ctd\u003ePN-010-REN14-MFRKG\/US\/ \/V\u003c\/td\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e-1...10 bar \/ -14.6...145 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible overpressure\u003c\/td\u003e\n\u003ctd\u003e75 bar\u003c\/td\u003e\n\u003ctd\u003eBursting pressure (min.)\u003c\/td\u003e\n\u003ctd\u003e150 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring element\u003c\/td\u003e\n\u003ctd\u003eceramic-capacitive measuring cell\u003c\/td\u003e\n\u003ctd\u003eProcess connection\u003c\/td\u003e\n\u003ctd\u003e1\/4\" NPT external thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput function\u003c\/td\u003e\n\u003ctd\u003e2 x switching; 1 x analogue (configurable)\u003c\/td\u003e\n\u003ctd\u003eAnalogue output\u003c\/td\u003e\n\u003ctd\u003e4...20 mA \/ 0...10 V (scalable 1:5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy \/ switch point\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; ± 0.4 % span\u003c\/td\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eIO-Link COM2, revision 1.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1.5 ms\u003c\/td\u003e\n\u003ctd\u003eOperating voltage\u003c\/td\u003e\n\u003ctd\u003e18...30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 35 mA\u003c\/td\u003e\n\u003ctd\u003eMedium \/ ambient temperature\u003c\/td\u003e\n\u003ctd\u003e-25...80 °C \/ -25...80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWetted materials\u003c\/td\u003e\n\u003ctd\u003estainless steel (316L \/ 1.4404); Al2O3 ceramics; FKM\u003c\/td\u003e\n\u003ctd\u003eElectrical connection \/ protection\u003c\/td\u003e\n\u003ctd\u003eM12 connector; IP 65 \/ IP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003ePN2694 Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/media.ifm.com\/dam\/0f6a3d04-6189-4893-9b4e-f094bded366d\/Original\/PN2694-01_EN-GB.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eIFM PN2694 · PDF · Official IFM document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch2\u003ePN2694 – Frequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003cdiv class=\"ha-faq\"\u003e\n\u003cdetails class=\"ha-faq-item\"\u003e\u003csummary class=\"ha-faq-q\"\u003eWhat is the measuring range and overload rating of the PN2694?\u003c\/summary\u003e\u003cp class=\"ha-faq-a\"\u003eThe PN2694 measures -1...10 bar (-14.6...145 psi), with a permissible overpressure of 75 bar and a bursting pressure of 150 bar.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails class=\"ha-faq-item\"\u003e\u003csummary class=\"ha-faq-q\"\u003eWhat measuring element does the PN2694 use and what media can it monitor?\u003c\/summary\u003e\u003cp class=\"ha-faq-a\"\u003eIt uses a ceramic-capacitive measuring cell and is suitable for liquids and gases in industrial applications.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails class=\"ha-faq-item\"\u003e\u003csummary class=\"ha-faq-q\"\u003eHow accurate is the PN2694?\u003c\/summary\u003e\u003cp class=\"ha-faq-a\"\u003eThe switch-point setting accuracy is \u0026lt; ± 0.4 % of the span.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails class=\"ha-faq-item\"\u003e\u003csummary class=\"ha-faq-q\"\u003eWhat outputs does the PN2694 provide?\u003c\/summary\u003e\u003cp class=\"ha-faq-a\"\u003eTwo configurable switching outputs plus one analogue output selectable as 4...20 mA or 0...10 V and scalable 1:5.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails class=\"ha-faq-item\"\u003e\u003csummary class=\"ha-faq-q\"\u003eDoes the PN2694 support IO-Link and how fast does it respond?\u003c\/summary\u003e\u003cp class=\"ha-faq-a\"\u003eYes, it supports IO-Link COM2 (revision 1.1) and has a response time of \u0026lt; 1.5 ms.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails class=\"ha-faq-item\"\u003e\u003csummary class=\"ha-faq-q\"\u003eWhat is the PN2694 operating voltage and protection?\u003c\/summary\u003e\u003cp class=\"ha-faq-a\"\u003eIt operates on 18...30 V DC, draws \u0026lt; 35 mA, and includes short-circuit and reverse-polarity protection.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails class=\"ha-faq-item\"\u003e\u003csummary class=\"ha-faq-q\"\u003eWhat materials contact the medium and what is the IP rating?\u003c\/summary\u003e\u003cp class=\"ha-faq-a\"\u003eWetted parts are stainless steel (316L \/ 1.4404), Al2O3 ceramics and FKM; enclosure protection is IP 65 \/ IP 67.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails class=\"ha-faq-item\"\u003e\u003csummary class=\"ha-faq-q\"\u003eWhat is the process connection and display of the PN2694?\u003c\/summary\u003e\u003cp class=\"ha-faq-a\"\u003eA 1\/4\" NPT external thread with an M12 connector and a rotatable 4-digit red\/green alphanumeric display.\u003c\/p\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"BreadcrumbList\", \"itemListElement\": [{\"@type\": \"ListItem\", \"position\": 1, \"name\": \"Home\", \"item\": \"https:\/\/www.creativeautomation.ae\/\"}, {\"@type\": \"ListItem\", \"position\": 2, \"name\": \"Electrical Automation \u0026 Cables\", \"item\": \"https:\/\/www.creativeautomation.ae\/collections\/electrical-automation-cables\"}, {\"@type\": \"ListItem\", \"position\": 3, \"name\": \"Automation \u0026 Control Gear\", \"item\": \"https:\/\/www.creativeautomation.ae\/collections\/automation-control-gear\"}, {\"@type\": \"ListItem\", \"position\": 4, \"name\": \"Sensors\", \"item\": \"https:\/\/www.creativeautomation.ae\/collections\/sensors\"}, {\"@type\": \"ListItem\", \"position\": 5, \"name\": \"Pressure Sensors\", \"item\": \"https:\/\/www.creativeautomation.ae\/collections\/pressure-sensors\"}, {\"@type\": \"ListItem\", \"position\": 6, \"name\": \"IFM PN2694 - Pressure Sensor with Display, -1...10 bar, 1\/4\\\" NPT External\", \"item\": \"https:\/\/www.creativeautomation.ae\/products\/pn2694\"}]}\u003c\/script\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the measuring range and overload rating of the PN2694?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The PN2694 measures -1...10 bar (-14.6...145 psi), with a permissible overpressure of 75 bar and a bursting pressure of 150 bar.\"}}, {\"@type\": \"Question\", \"name\": \"What measuring element does the PN2694 use and what media can it monitor?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It uses a ceramic-capacitive measuring cell and is suitable for liquids and gases in industrial applications.\"}}, {\"@type\": \"Question\", \"name\": \"How accurate is the PN2694?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The switch-point setting accuracy is \u003c ± 0.4 % of the span.\"}}, {\"@type\": \"Question\", \"name\": \"What outputs does the PN2694 provide?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Two configurable switching outputs plus one analogue output selectable as 4...20 mA or 0...10 V and scalable 1:5.\"}}, {\"@type\": \"Question\", \"name\": \"Does the PN2694 support IO-Link and how fast does it respond?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes, it supports IO-Link COM2 (revision 1.1) and has a response time of \u003c 1.5 ms.\"}}, {\"@type\": \"Question\", \"name\": \"What is the PN2694 operating voltage and protection?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It operates on 18...30 V DC, draws \u003c 35 mA, and includes short-circuit and reverse-polarity protection.\"}}, {\"@type\": \"Question\", \"name\": \"What materials contact the medium and what is the IP rating?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Wetted parts are stainless steel (316L \/ 1.4404), Al2O3 ceramics and FKM; enclosure protection is IP 65 \/ IP 67.\"}}, {\"@type\": \"Question\", \"name\": \"What is the process connection and display of the PN2694?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"A 1\/4\\\" NPT external thread with an M12 connector and a rotatable 4-digit red\/green alphanumeric display.\"}}]}\u003c\/script\u003e","brand":"IFM","offers":[{"title":"Default Title","offer_id":45489937940617,"sku":"PN2694","price":2328.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0693\/5622\/4649\/files\/1uhMlE8iXnINhNt6flVJwjqAk11R8jkLc.jpg?v=1785565289","url":"https:\/\/www.creativeautomation.ae\/products\/pn2694","provider":"Creative Industrial Automation","version":"1.0","type":"link"}