{"product_id":"mk5107","title":"IFM MK5107 - T-Slot Cylinder Sensor, T-Slot Drop-In, 10 kHz","description":"\u003cp\u003eIFM MK5107 T-Slot Cylinder Sensor — magnetic T-slot cylinder sensor, drop-in self-locking, 10 kHz switching, 0.3 m moulded cable. Magnetic T-slot cylinder sensor, PNP N\/O, response 2.8 mT, 10000 Hz switching, self-locking clamp, 0.3 m PUR + M12, 10...30 V DC, IP67.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN \/ SKU:\u003c\/strong\u003e MK5107\u003c\/p\u003e\u003ch2\u003eMK5107 Applications\u003c\/h2\u003e\u003cp\u003eThe IFM MK5107 is a magnetic cylinder position sensor used for end-position detection on pneumatic cylinders with a T-slot. It is suited for confirming piston position on clamping, gripping and feed cylinders in assembly and handling machinery. It drops into the slot from the top and self-locks for quick mounting and easy adjustment, the moulded cable provides very good strain relief, and a very high 10 kHz switching frequency with fast travel-speed capability suits high-cycle automation. Clearly visible LED shows switching status.\u003c\/p\u003e\u003ch2\u003eMK5107 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eIFM\u003c\/td\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eT-slot cylinder sensor (magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eIFM Type Code\u003c\/td\u003e\n\u003ctd\u003eMKT3028BBPKG\/G\/0,3M\/ZH\/US\u003c\/td\u003e\n\u003ctd\u003eElectrical Design\u003c\/td\u003e\n\u003ctd\u003ePNP\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOutput Function\u003c\/td\u003e\n\u003ctd\u003eNormally open\u003c\/td\u003e\n\u003ctd\u003eCylinder Type\u003c\/td\u003e\n\u003ctd\u003eT-slot cylinders\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eResponse Sensitivity\u003c\/td\u003e\n\u003ctd\u003e2.8 mT\u003c\/td\u003e\n\u003ctd\u003eSwitching Frequency\u003c\/td\u003e\n\u003ctd\u003e10000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTravel Speed\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 m\/s\u003c\/td\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eSelf-locking fixture, drop-in from top\u003c\/td\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e10...30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 mA\u003c\/td\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP 65 \/ IP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003e-25...85 °C\u003c\/td\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003e0.3 m PUR cable + M12, A-coded, 4 contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e21.1 g\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eMK5107 Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/media.ifm.com\/dam\/4dc922df-5841-40a5-b4d9-20e0a6a0ed36\/Original\/MK5107-02_EN-GB.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eIFM MK5107 · PDF · Official IFM document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch2\u003eMK5107 -- Frequently Asked Questions (FAQ)\u003c\/h2\u003e\u003cdiv class=\"ha-faq\"\u003e\n\u003cdiv class=\"ha-faq-item\"\u003e\n\u003cp class=\"ha-faq-q\"\u003eWhat is the IFM MK5107?\u003c\/p\u003e\n\u003cp class=\"ha-faq-a\"\u003eIFM MK5107 is a T-Slot Cylinder Sensor -- magnetic T-slot cylinder sensor, drop-in self-locking, 10 kHz switching, 0.3 m moulded cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ha-faq-item\"\u003e\n\u003cp class=\"ha-faq-q\"\u003eWhat is the IFM MK5107 used for?\u003c\/p\u003e\n\u003cp class=\"ha-faq-a\"\u003eThe IFM MK5107 is a magnetic cylinder position sensor used for end-position detection on pneumatic cylinders with a T-slot.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ha-faq-item\"\u003e\n\u003cp class=\"ha-faq-q\"\u003eWhat are the key specifications of the IFM MK5107?\u003c\/p\u003e\n\u003cp class=\"ha-faq-a\"\u003eIFM MK5107 -- Magnetic T-slot cylinder sensor, PNP N\/O, response 2.8 mT, 10000 Hz switching, self-locking clamp, 0.3 m PUR + M12, 10...30 V DC, IP67.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ha-faq-item\"\u003e\n\u003cp class=\"ha-faq-q\"\u003eWhat output or connection does the IFM MK5107 have?\u003c\/p\u003e\n\u003cp class=\"ha-faq-a\"\u003eThe IFM MK5107 has -- Output: Normally open.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ha-faq-item\"\u003e\n\u003cp class=\"ha-faq-q\"\u003eWhere can I get the IFM MK5107 datasheet?\u003c\/p\u003e\n\u003cp class=\"ha-faq-a\"\u003eThe official IFM MK5107 datasheet (PDF) is linked in the Datasheet \u0026amp; Manual section on this page.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cstyle\u003e.ha-faq{margin-top:8px}.ha-faq-item{border-top:1px solid #eee;padding:8px 0}.ha-faq-q{font-weight:700;color:#1a1a1a;margin:0 0 3px}.ha-faq-a{margin:0;color:#333}\u003c\/style\u003e","brand":"IFM","offers":[{"title":"Default Title","offer_id":47702025404553,"sku":"MK5107","price":234.97,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0693\/5622\/4649\/files\/MK5107.jpg?v=1785417004","url":"https:\/\/www.creativeautomation.ae\/products\/mk5107","provider":"Creative Industrial Automation","version":"1.0","type":"link"}