{"product_id":"ac009s","title":"IFM AC009S - AS-Interface Safety Module, 2 Safe Inputs, SIL3 Relay","description":"\u003cp\u003eIFM AC009S AS-Interface Safety Module — AS-i SmartLine safety module, 2 safe inputs + 2 relay outputs, SIL3 \/ PLe, DIN-rail. AS-Interface safety module, 2 safe inputs (cross-monitored) + 2 relay outputs, SIL3 \/ ISO 13849 PLe, DIN-rail, 26.5...31.6 V DC, IP20.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN \/ SKU:\u003c\/strong\u003e AC009S\u003c\/p\u003e\u003ch2\u003eAC009S Applications\u003c\/h2\u003e\u003cp\u003eThe IFM AC009S is an AS-Interface control cabinet safety module used to connect mechanical safety switches to an AS-i safety network. It is suited for E-stop, guard-door and interlock monitoring on machines using AS-i Safety at Work. It provides two safe inputs with cross-monitoring and two relay outputs, meets ISO 13849-1 Category 4 PLe and IEC 61508 SIL3, and uses powerful LEDs to show operation, switching status and errors. The space-saving DIN-rail housing wires quickly via screw terminals.\u003c\/p\u003e\u003ch2\u003eAC009S Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eIFM\u003c\/td\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAS-Interface control cabinet safety module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eIFM Type Code\u003c\/td\u003e\n\u003ctd\u003eSmartLine SafetyModul\u003c\/td\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e2 x safe input (PNP, cross-monitored)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e2 x relay (24 V DC \/ 10...240 V AC, 6 A ohmic)\u003c\/td\u003e\n\u003ctd\u003eSafety Rating\u003c\/td\u003e\n\u003ctd\u003eSIL3 (IEC 61508); Cat 4 PLe (ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePFH\u003c\/td\u003e\n\u003ctd\u003e4E-09 \/h\u003c\/td\u003e\n\u003ctd\u003eAS-i Profile\u003c\/td\u003e\n\u003ctd\u003eS-7.B.E; AS-i v2.11 \/ 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e26.5...31.6 V DC (AS-i)\u003c\/td\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail TH35 (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e93 x 25.4 x 108 mm\u003c\/td\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003e-25...50 °C\u003c\/td\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003ePC-GF20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003eScrew terminals \/ pin headers\u003c\/td\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e258 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eAC009S Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/media.ifm.com\/dam\/df71e6c6-e7d4-4e52-9ff0-77009b75629d\/Original\/AC009S-03_EN-GB.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eIFM AC009S · PDF · Official IFM document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch2\u003eAC009S -- Frequently Asked Questions (FAQ)\u003c\/h2\u003e\u003cdiv class=\"ha-faq\"\u003e\n\u003cdiv class=\"ha-faq-item\"\u003e\n\u003cp class=\"ha-faq-q\"\u003eWhat is the IFM AC009S?\u003c\/p\u003e\n\u003cp class=\"ha-faq-a\"\u003eIFM AC009S is a AS-Interface Safety Module -- AS-i SmartLine safety module, 2 safe inputs + 2 relay outputs, SIL3 \/ PLe, DIN-rail.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ha-faq-item\"\u003e\n\u003cp class=\"ha-faq-q\"\u003eWhat is the IFM AC009S used for?\u003c\/p\u003e\n\u003cp class=\"ha-faq-a\"\u003eThe IFM AC009S is an AS-Interface control cabinet safety module used to connect mechanical safety switches to an AS-i safety network.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ha-faq-item\"\u003e\n\u003cp class=\"ha-faq-q\"\u003eWhat are the key specifications of the IFM AC009S?\u003c\/p\u003e\n\u003cp class=\"ha-faq-a\"\u003eIFM AC009S -- AS-Interface safety module, 2 safe inputs (cross-monitored) + 2 relay outputs, SIL3 \/ ISO 13849 PLe, DIN-rail, 26.5...31.6 V DC, IP20.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ha-faq-item\"\u003e\n\u003cp class=\"ha-faq-q\"\u003eWhat output or connection does the IFM AC009S have?\u003c\/p\u003e\n\u003cp class=\"ha-faq-a\"\u003eThe IFM AC009S has -- Output: 2 x relay (24 V DC \/ 10...240 V AC, 6 A ohmic).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ha-faq-item\"\u003e\n\u003cp class=\"ha-faq-q\"\u003eWhere can I get the IFM AC009S datasheet?\u003c\/p\u003e\n\u003cp class=\"ha-faq-a\"\u003eThe official IFM AC009S datasheet (PDF) is linked in the Datasheet \u0026amp; Manual section on this page.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cstyle\u003e.ha-faq{margin-top:8px}.ha-faq-item{border-top:1px solid #eee;padding:8px 0}.ha-faq-q{font-weight:700;color:#1a1a1a;margin:0 0 3px}.ha-faq-a{margin:0;color:#333}\u003c\/style\u003e","brand":"IFM","offers":[{"title":"Default Title","offer_id":47702025044105,"sku":"AC009S","price":946.11,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0693\/5622\/4649\/files\/AC009S.jpg?v=1785416991","url":"https:\/\/www.creativeautomation.ae\/products\/ac009s","provider":"Creative Industrial Automation","version":"1.0","type":"link"}